solar iboost problems. I have found that charging the battery with surplus solar PV is no problem, the battery takes the power. solar iboost problems

 
 I have found that charging the battery with surplus solar PV is no problem, the battery takes the powersolar iboost problems  I've just had panels fitted and the installers also fitted a solar iboost, which is apparently for immersion heaters

6. Establish a Pairing Between Solar iBoost & the Sender. Tel: +44 (0) 1536 201588 Email: [email protected] Mon to Thur 08. Solar iboost is an essential addition to any solar pv installation if you also have a conventional immersion heater. Some have owned their solar panels for a decade. Ajax123. 22deg pitch East to west 12 panels on the East and 8 on the West. Where an export meter is fitted the benefits of the Solar iBoost can still easily outweigh the rising energy costs of water heating. With the Sender in hand and batteries fitted stand about 1-2 metres away from the Solar iBoost. For instrustructions on how to install the Solar iBoost + please refer to your installlation manual or visit. All it takes is 2-3 hours of sunshine for the iBoost to heat a tank. I’ve heard devices like this can cause flicker; does the Solar iBoost+ have this problem? The Solar iBoost+ uses a special switching method to switch power into the immersion heater, thisIt is the thermostat in the immersion he is talking about - it is new and ought to be working to cut off the iboost at the desired temperature. Druk op een willekeurige knop op de Solar iBoost+ om de achtergrondverlichting in te schakelen. Hi Apologies in advance, im looking at monitoring a new solar panel install with an iboost diverter. . Using just a single clamp installed at the household meter, the sender transmits vital export energy information to the Solar iBoost+ wirelessly. Tel: +44 (0) 1536 201588 Email: [email protected] Mon to Thur 08. The most common – and most serious – problem owners face is with the inverter. The Solar iBoost+ automatically heats up to 2 immersions. More than seven in 10 owners in our survey had never had a technical fault with their solar panel system. The only problem we have had was with the controller after a thunderstorm, we have fitted several MOV sets on the downline in the hope that this would drain any spikes to earth before they get to the controller, so far so good. Sensor for when water is Hot, (when the tank is fully hot, iBoost displays Hot) I have a Marlec Solar Iboost+ solar diverter which communicates to it's display unit on 868. The Solar iBoost+ main unit has a built in display, simply touch any button and the back light illuminates, if energy is flowing “Heating by Solar xx. 1. Fitting a Solar iBoost maximises consumption of the free solar energy generated at your property. 52kWp) east facing, 11 x Tigo optimizers & cloud, Growatt. View and Download Marlec Solar iBoost+ troubleshooting manual online. 00Our Rheem heat-pump is on the fritz. Solic200 Controller Data Sheet. T: 0800 201 4527. We have 6kW of solar panels and a large hot water tank (220litres) with two immersion heaters, top and bottom. Remote Survey. Operating temperature range: 0 to 40 ºC. Typically 3-4 weeks of battery life will remain when the message first appears. When viewing head-on there is a lot of information that reveals itself on the lcd panel. Panels run the house and PW fills first. If changing it made no difference then you've probably. Využijte Solar iBoost+ na solární ohřev vody z přebytků elektřiny z vaší fotovoltaické elektrárny. It intelligently controls and adjusts the flow of energy to the immersion in proportion with the fluctuating export levels. #2: SOLiC 200 Solar Immersion Controller. My current immersion heater is 3kw. • Maximise the use of the free solar energy generated at your property. Tel: +44 (0) 1536 201588 Email: [email protected] Mon to Thur 08. As for the energy bills: the bills look. ActivationMarlec Engineering Co Ltd Rutland House Trevithick Road Corby, Northants NN17 5XY. Today much better. ," says Dr Rong Deng, an. The STA works with its members to achieve the right regulatory framework and incentives for solar to deliver an increasing contribution to the UK’s electricity and heating needs. For battery systems with a higher cut-in the Sender 250 is available on line to retro-fit in place of the existing Sender, this cuts-in the Solar iBoost+ at 250W. London. 443p) that's a potential saving of. Hi all. Positioning should be convenient for running a cable from a fused spur to the Solar iBoost+ and on to the immersion heater(s). Name. London. It has a voltage range of 220 V to 240 V, a maximum load of 3 kW, and weighs 1. A message on the display details the specific problem:. The immersions should have thermostat controls but no electronic controls between the Solar iBoost+ and the immersion. 17 January 2022 at 9:36PM. Hard wire the Solar iBoost+ in accordance with the selected wiring diagram on pages 7-9, noting the warnings on page 8. 16 Hyundai 400kw all black panels w/ optimisers, 6kw Solaredge HD Wave inverter, Solar Iboost with two immersion heaters on one 240l hw tank. Effortlessly track and manage your home’s energy consumption with the iBoost+ Buddy. 4) It must be correctly wired. The Solar iBoost and Sender unit have an electronic pairing so that units in close proximity do not interfere with each other. A user reports a broadband problem with a Solar iBoost device that he installed to heat his water tank with solar power. i have already noticed 1 issue and that is the iBoost refuses to work. It depends whether you believe a ~£500 investment is worth the money for a marginal return when the iBoost is already doing the same, all you’ll gain is a visibility of energy flow and controls, but you could do the latter with a £10 smart socket too. Still not working, mostly says "water hot" but occaionally you get the flashing blue light which indicates water heating by solar BUT it takes the full 3kw even when not generating 3kw and says heating off while doing it. at our current energy rate with Bulb (12. 00 Ex. Solar iBoost can handle 3kw immersion no problem so you may as well get that. If the house load increases beyond solar the iBoost cuts out. 4) It must be correctly wired. London. Hi. 00 - Fri 08. 6kW 320L immersion tank with 2-5 adults living in the house. The Solar iBoost also comes with interchangeable settings for winter and summer. 'Normal' system Solar PV System 2: 3. SolarEdge system. The manual says to configure it as "Storage only" which you can do, but if you configure it as "AC Battery" then it'll display properly in the app. Two chickens: 1 Light Sussex, 1 Speckled Rock. The iBoost is designed to use any spare (exported) power, over that 100W threshold. 6. 27 Sep 25, 2022 #1 Morning all I have just bought some devices and hoping someone has the same or similar setup who can help me understand how to optimise. Built in hot water timer with added Boost function. Leaf 62kwh plus Zappi. VAT) All Products Energy Storage. 6kwh today, however a bit later it said it had saved 16. Have solar PV with a iboost +. I have had it in and running for a while in the background without paying my attention to it. net. 6 kw east facing), Solis inverters, Solar. The immersion should be rated ≤ 3kW and it MUST. As other manufacturers become more aware of the technology, we. 6kWp system, 20 x 300W Longi Solar panels with a Solis 6. Additional system controls The Solar iBoost+ internal diagnostics notify if any problem arises in the system. Solar iBoost Review. The more efficient a panel is the higher its optimum. How to Install the Solar iBoost Original. When a problem is detected the red warning triangle on the front of the unit is illuminated. 5 Growatt Smart Battery, iBoost Hot water booster. Solar iBoost+ allows you to self consume more of your PV generated energy! Use your PV system to heaNorthern Lincolnshire. Since installation of the iBoost on 15th March this year we have ‘saved’ 1770kWh which at 16p per kWh equates to £283. How to set the Timed Boost on the Solar iBoost+. stag. the Solar iBoost, observing all clearances shown on page 6. 1). Solar inverters are a key component of any solar power system, they convert DC power from the panels into AC power output that can be used by household appliances. Solar PV panels are well worth considering if you have a mainly south-facing roof with little or no shade. Common signs of solar overheating. 30 to 17. It is linked up ok, i have restarted the unit a couple of times. Optional in-home display with remote control to Solar iBoost+. 2. Solar PV System 1: 2. 10 March 2022 at 4:48PM. Which are programmable on a 5/2 day basis. I use a smart plug to monitor my iBoost in Home Assistant. It's connected to one phase of my 11kw, 3ph turbine so putting in about 3-3. A very basic question, is it possible to connect to the iboost ct signal to obtain the export and remove the need for another ct clamp to be fitted to measure export? TIA I am not familiar with the iBoost, but my Immersun plus a CT gave me most, if not all, of the information and facilities of my new Eddi, just a bit noisy because the Immersun was fan cooled. 5A. I appear to have 2 problems. If it works during daylight, it will start to heat the water properly. However, I would like to change the way the system works- specifically, I want my excess generation to go first to my immersion heater, then, when the tank is hot I would like any excess to. Follow the guidance and contact Marlec for. Has any one any comments on these fitting etc. Solar iBoost+™ FAQ’s; Solar iBoost™ User Operating Help;. · Gardez le Buddy à portée de main afin de pouvoir vérifier le voyant indicateur d'énergie intuitif. North Yorkshire. 16 Hyundai 400kw all black panels w/ optimisers, 6kw Solaredge HD Wave inverter, Solar Iboost with two immersion heaters on one 240l hw tank. Solar IBoost. There must not be any electronic, relay or contactor switching devices between the Solar iBoost and the immersion. We have a solar iboost which was working fine then suddenly stopped. Connection 3. 85kW. 00 incl. Does the device somehow send only your excess solar watts to the tank or must it be the full 2. It saves you money by cutting the cost of water heating and reduces the use of your home’s boiler. 28kwh solar array split across two parts of a hiopped roof, a 3KW GroWAtt inverter, and an iBoost My house is similar to yours in setup - there's a small Potteron boiler that provides hot water and central heating, the boiler feeds an unvented cylinder in the loft space which stores hot water for the days use. Rob_the_rich Sock Muncher. If the sensor detects that the property is exporting electricity, the device diverts the excess power to the immersion heater in the hot water tank. the Solar iBoost+, observing all clearances shown on page 6. 2. i have been asked to fit an i boost to an existing system that has solar panels. From United Kingdom Anon. The Solar iBoost+ automatically heats up to 2 immersions. Our Process. does the screen become fully readable with clarity. It adjusts the energy flow to the immersion heater as your home consumption varies; ensuring that only excess power is used. Cost of £11,700 incl. A message on the display details the specific problem:. Solar PV System 1: 2. Solar iBoost je urþen pro zásobníky teplé vody s ponorným oh ívaþem o jmenovitém výkonu do 3kW, který MUSÍ být vybaven funkþním termostatem. - 10 6 550W SHARP BiFacial Panels SE 3680 HD Wave Inverter SE Optimizers. And then suddenly, out of the blue it starts working again. Is this an iBoost problem rather than a heating system problem? Or has my thermostat failed?. Last edited by Sunking; 03-11-2017, 05:18 PM . Slightly concerning for a while, as it sits on the same fused spur as our ASHP controller, and our solar inverter gets its mains feed from the same trip switch. c. Note: Solar iBoost+ and Solar iBoost (original) models prior to April 2019 are also compatible alongside battery systems with thresholds under 100W without any changes normally. I have a growatt system using a hybrid inverter and 6 kw battery plus an Iboost controller to heat the immersion heater. - Current flow is often increased, which can blow fuses, MCB tripping or burnt accessories - A tripping MCB may prevent it starting. VAT (£ 795. Interestingly I have now had replies from the two suppliers, solar iboost, and the solic 200 from earthwise products, the Solic 200 comes with a 10 year rtb warranty and they have offered a credible trade account, the solar iboost is a 2 year warranty and they fobbed me off with an explanation about the person who is selling on eBay (who has indicated sales of 515 units) explaining that they. Then, batteries help store this. With Over 120,000 already installed by professional. SIB Energy Limited ⁞ Corby ⁞ NN17 5XY Further Support To find out more about how Solar. 2. Hard wire the Solar iBoost+ in accordance with the selected wiring diagram on pages 7-9, noting the warnings on page 8. 1. Fit one Solar iBoost+ onto each phase, each with up to 3kW of load. Messages. . It probably works on the same principle as an Eddi. Solar iBoost Solar Immersion Controller range for sale at finaly made sense for me to buy a Solar IBoost+ due to increasing Gas and Electricity costs. The red warning triangle illuminates and the message Sender Battery Low also appears on the screen. My iBoost says "water Hot" all the time now and i cant get it to divert any power. Fit one Solar iBoost+ onto each phase, each with up to 3kW of load. Between those two, the problem is now solved. Could have just turned the boiler off and do an occasional manual boost. 80 inc. 2/ Boost. What is an iBoost? So, what a solar panel system really gives you is electricity – which is great. CT Clamp question. Installation Positioning The Solar iBoost+ unit is typically located close to the hot water tank (airing cupboard or similar) and electrically connected between a fused outlet or MCB and the immersion heater. Price adjustmentCharge your car with grid, wind or solar energy. Connected my laptop to the test socket inside the Master Socket. I have spent the last year manually boosting. Devices such as the Marlec solar iboost detect when you are exporting more than 100 watts to the grid and can divert your excess production to the hot water tank. Connection 3. Marlec Engineering Co Ltd Rutland House Trevithick Road Corby, Northants NN17 5XY. I'm posting this now because the solar company has gone AWOL and are refusing to come back to fix things. Giving you free hot water!Check out this device. It was not what I expected but the more I thought about i. Om te programmeren: 1. The SOLiC 200 is an intelligent immersion heater controller that automatically converts energy generated by existing PV panels into hot water by diverting excess solar power to the immersion heater before it’s exported to the national grid. 1. Trace it down. (The iBoost+ Buddy is suitable for homeowners to install)Award winning British made immersion controller. 'Normal' system. Apr 30, 2014. Free Hot Water From Your PV Array With Solar iBoost+ The UK's Best Selling PV Accessory. its one of those " open here to void the warranty" things. All was fine when the electrician from the solar company showed me the system, but 2 hours later, I switched the kettle on and the RCD tripped. For more information or for technical queries please contact the team on 01243 641830. If the fan is dirty or obstructed, it can cause the inverter to make noise. When the unit is first supplied, the sender will be pre-paired to the iBoost and not require further action. The most easy to use interface. This prevents panels from freezing but introduces new problems in the…I have a solar iboost and the main box has no display, voltage going in is fine but nothing coming out, it's 3-4 years old. I hoped to use the iboost to probably heat all my water in summer and certainly it was a good. It's about 3 years old. If you limit the Solis backflow limit to 100W the iBoost will have noting to use. The Sender allows the cut-in to be set at 250W of export (Standard settings are 100W - Solar iBoost+ & 200W - Solar iBoost original). Is it supposed to be directly. First thing I did was disconnect the thermostat - system still tripped off, so checked the box itself and discovered there was a short inside, so that's it. As the iBoost will only ever run at a maximum load of 3000w I have not hard wired mine, instead its on a 3 pin plug and its never been an issue in over 4 years. 7kW facing south & 2. The other set of tails goes to the house CU which is. 0 inverter + Wifi and iBoost. Weight 2kg. The main unit is working fine and pairs with the sender. The iBoost immersion system was not connected properly and we ended up with no hot water for a few days. "START" AND "CANCEL" to "Start" and "Cancel" for the button press labels. 6 kw east facing), Solis inverters, Solar IBoost water heater, Mitsubishi SRK35ZS-S and SRK20ZS-S Wall Mounted Inverter Heat Pumps, ex Nissan Leaf owner) 1. Positioning should be convenient for running a cable from a fused spur to the Solar iBoost+ and on to the immersion heater(s). Overheating can damage the inverter itself, reducing its lifespan and. 66kWp) south facing, 4 x JASolar 380w panels (1. It simply says Water Tank: Hot. 2. 30 to 15. Ideal for customers adding battery storage with a cut-in around the same level as their Solar iBoost. It would appear that the issue sits with the way the Iboost monitors the export and incorrectly decides to cut in. How can the iboost override the tank. We have a 3. Quick Find: 8811. 21 September 2019 at 3:20PM. This reduces the need to draw additional power from the grid and promotes greater. and feeding that through a filter, necessarily inductive, you have the same problem - except that you can’t use a flywheel diode. I have recently had a 2. The display is completely. £115 (No VAT, outside of UK) Pay Monthly Finance on orders from £2k - £30k. This is the case whether I am charging the car or not. 34. the Solar iBoost+, the clamp and immersion to the phase with the lowest load. 65KW solar PV system installed and am considering a solar iboost water heater. . The Solar iBoost+ output must be the only supply to the immersion heaters and connected through a good quality, working mechanical thermostat. You need to find the single set of tails after the summation point. The iBoost power control electronics uses a semiconductor switch not a mechanical one like a relay because it can be turned on/off very quickly. Northern Lincolnshire. 4kwh system, South facing. Solar iBoost+ ADD ON - Buddy - Monitor home energy usage from the iBoost. Connected my laptop to the test socket inside the Master Socket. This can create the following problems: - RCD will trip if its on an protected power feed. Has anybody experience solar iboost creating problems with immersion heater safety cut out? Does the iboost somehow heat the tank higher. Decreasing current draw 5% may increase voltage 15%, and that's a win. It depends whether you believe a ~£500 investment is worth the money for a marginal return when the iBoost is already doing the same, all you’ll gain is a visibility of energy flow and controls, but you could do the latter with a £10 smart socket too. Ivar 5 Wood Burning Stove. The Solar iBoost concept is to use the surplus photovoltaic energy generated at your home to heat the water in your household water tank and save you money. Instead of losing this unused energy, you can redirect it to heat water, thus increasing your energy self-consumption. Cutting the cost of your water heating, and reducing the strain on your boiler. The iBoost+ Buddy is a wireless home energy monitor and remote control for your Solar iBoost+. Reading the Eddi documentation it seems to say it varies the amount diverted by changing the voltage. The Sender allows the cut-in to be set at 250W of export (Standard settings are 100W - Solar iBoost+ & 200W - Solar iBoost original). The boiler allows up to 60degC as infeed and will fire up to heat the water to 60 if it enters at a lower temperature. Electrical & Fixing Accessories. 5. show you how to be sure that your small DIY Solar system is properly charging the battery through the charge controller. 00 - Fri 08. 8 kWp system, (4. 5 billion solar panels. The cooling fan on my iBoost failed after 5 years, I contacted Taylor in the sales department who immediately identified the problem and sent a replacement fan within 3 working days the problem was resolved. 6kw solid hybrid with 5. 2. Reply to TJ Anderson. ONE set of tails goes to the garage, which is where the solar PV power is coming from. Has solar panels installed last week and the iboost+ then made the hot water too hot to touch. 25K views 8 years ago. For use with Solar iBoost+. I have had problems with seized stop cocks over the years and last time my plumber fitted me an Surestop stop !!!! with a remote switch on the house side of the existing under sink stop !!!!. The Solar iBoost unit is typically located close to the hot water tank (airing cupboard or similar) and electrically connected between a fused outlet or MCB and the immersion heater. Hard wire the Solar iBoost+ in accordance with the selected wiring diagram on pages 7-9, noting the warnings on page 8. The Solar iBoost+ internal diagnostics notify if any problem arises in the system. failure of the expansion vessel. Solar iBoost. Solar iBoost+ allows you to self consume more of your PV generated energy! Use your PV system to heaSolar iBoost’s built in display means that you can watch your savings grow, simply press the display button to see Saved Today, Saved Yesterday, Saved 7 Days, Saved 28 Days and Total Saved readings. Crowmann Forumite Posts: 136 Forumite. Hi, We're replacing our boiler and everything seems to be pointing towards a combi boiler, especially looking at this list of pros and cons. 00Press any button on the Solar iBoost+ to switch on the backlight. Keep the Sender at 1-2m from the main unit. Wireless sensor clamp - Ensuring only surplus energy is used. I use my Iboost in conjunction with solar panels with micro inverters. butterfield. Within 90 days. Cutting the cost of heating your water. Generally very happy with it, but I'm not clear if the iboost is set up how I want and I'm finding the user guide unhelpful. Reply to bigspark17. barneyd · #12 · Aug 5, 2022. still tripping. Hard wire the Solar iBoost in accordance with the selected wiring diagram on page 7 following the IEE Regulations or local regulations. the Solar iBoost+, observing all clearances shown on page 6. I'm not sure of the justification for this device. We offer 3 different types of power diverters for our customers who could be looking for 3 different solutions. It’s a need to know thing. Flexible & Semi Flexible Solar Panels. Ordinary solar panels have a capacity of about 400W, so if you count both rooftops and solar farms, there could be as many as 2. Extended warranty, parts, education & more. When the batteries are fully charged power is diverted to hot water via a Solar iBoost+ unit in conjunction with a Megaflo PV tank. The maximum power output from solar panels will be achieved for a south-facing roof with a tilt angle of between 30 ° and 45 ° with no shade. 30 to 15. Solar iBoost’s built in display means that you can watch your savings grow, simply press the display button to see Saved Today, Saved Yesterday,. 2 kw west facing panels , 3. T: 01257 443 377. This is its default mode of operation and when in this mode and if the water in the tank is not up to the temperature set, it will divert any surplus solar electricity to the immersion heater. CT Clamp question. Solar iBoost+ wirelessly 2 Solar iBoost+ is activated when excess energy is available. Join 100,000's Of Homeowners Who Are Already Saving Money On Their Hot Water Heating Bills. Hi All. Het eerste item van onderstaand menu wordt weergegeven (Set Time). Update to the Tesla Powerwall Problem With Solar IBoost. 2) The iboost must know that so the current transformer must be fitted the correct way around and must have batteries and be paired to main iboost. Other popular diverters include Eddi from Myenergi, closer to £400 in price, and the SolarEdge diverter which ranges from around £100-£400. - Current flow is often increased, which can blow fuses, MCB tripping or burnt accessories. I want to log solar generated, exported,diverted and home use. VAT (£ 249. Radio Range: 1 to 30M indoors (dependant on construction and local conditions) Operating radio Frequency: 868. The Solar Iboost monitors the incoming electricity supply and looks for power going back to the grid, this could be because you are generating more power than you are using in the. 6kW. Het eerste cijfer wordt actief en knippert. Solar iBoost problem. The system is still working, the solar iboost buddy is registering power usage and excess has been sent to the hot tank, but, the amount of power registered is not. Reply from Marlec Engineering Co. J. London. 'Charge Power Rate' can stay at 100% I think. The past few days have been poor for Solar. Looking for a little help with my iBoost. Solar iBoost+ announces battery compatibility with the addition of a new feature. Electricians Interview Trade Test. No solar energy will be captured by the Solar iBoost and timed settings will not operate. Put some distance between other devices and the sender and the problem is likely to be removed. Hardware News Network home page hnn bz. 3. Whether it’s related to the sender unit, wiring, or solar system performance, a patient and methodical approach can lead to a solution that gets your Solar iBoost. Phoned with a problem of a noisy fan in the Iboost and received details via an. Start with the Plug by measuring between the center pin and shell where you will find the short. Optional iBoost Buddy also now available. Hi. Libbi is a modular battery storage system that adapts to your needs. Can someone tell me what the resistance should be for a Solar iboost Clamp? My clamp is regestering zero ohms and I want to confirm this is the problem. ‎iBoost This application displays the current car battery's voltage, battery charging performance, engine start voltage connect to iBoost box via Bluetooth. I think they may work differently. Bit of a weird one. . Great customer service. Reply to iBoost goes dead and then a few days later, comes to life again in the Solar PV Forum | Solar Panels Forum area at ElectriciansForums. This is a problem that leaves far more at risk now than when LISAs launched in 2017. . With Over 120,000 already installed by professional. It was not what I expected but the more I thought about i. Affordable Solar PV Panel Systems, compatible with Social Energy & Agile Octopus. Establish a Pairing Between Solar iBoost & the Sender. Press and hold button B for 5 seconds then release. The system prioritises immersion 1 by checking back to it at 15 minute intervals. . Octopus Flux. #1. Hi Apologies in advance, im looking at monitoring a new solar panel install with an iboost diverter. Update to the Tesla Powerwall Problem With Solar IBoost. · Regardez l'affichage du Solar iBoost+ et activez à distance la fonction « Boost ». For instructions on how to programme the Battery Storage Offset on the Solar iBoost+ please. The Solar iBoost+ internal diagnostics notify if any problem arises in the system. The only thing it considers is correct battery voltage. Arms. Thinking about what video to make next, I asked myself what is my favourite bit of tech that I own. 3 MHz. 7. The iboost worked for just over 24hrs before it…for more informationThe Solar iBoost is a fantastic product to enable owners of solar PV systems to use even more of their free electri. The immersions should have thermostat controls but no electronic controls betweenMarlec Engineering Co Ltd Rutland House Trevithick Road Corby, Northants NN17 5XY. It was installed buy someone qualified but don't think they were use to working with an iboost. Same problems here in Co Mayo, Ireland. 30 to 15. Since the recent installation of my Zappi, my solar iboost is not detecting excess PV so instead of heating the water this is being diverted to the grid. Even if there was a problem with the clamp - it shouldn't be powering the immersion while saying water. Establish a Pairing Between Solar iBoost & the Sender. Connect the Measurement Clamp into the Sender and fit the batteries in the Sender. D. The Output of the Solar iBoost+ is a specially modulated DC output which must never be connected to the normal AC circuit. Solis inverters, Solar IBoost water heater, Mitsubishi SRK35ZS-S and SRK20ZS-S Wall Mounted Inverter Heat Pumps, ex Nissan Leaf owner) 0. The purpose of a solar water heating system is to heat your hot water via the sun. Comments. Tel: +44 (0) 1536 201588 Email: [email protected] Mon to Thur 08. Solar IBoost July 2, 2019 · Find your local Solar iBoost+ installer by entering your post code into our 'Find an installer map' and learn how you can start to save money by getting FREE hot water with the UK's best selling PV immersion controller.